1. Blog

What a validated lab result means, step by step

A validated lab result is one that has passed two kinds of checks. The first is analytical: the instrument and its quality controls show the measurement is reliable. The second is clinical: a qualified professional confirms the result makes sense for…

7 min de lectura

En este artículo
  1. The journey of a blood sample
  2. Analytical validation
  3. Clinical validation
  4. Why a change between two results may not mean much
  5. Reference ranges are not universal
  6. What happens to your sample at Santé Labs

A validated lab result is one that has passed two kinds of checks. The first is analytical: the instrument and its quality controls show the measurement is reliable. The second is clinical: a qualified professional confirms the result makes sense for that sample and that person. Only then is it released in your report.

Key takeaways

  • Most lab errors happen before or after the measurement, not inside the analyser [1][2].
  • Labs run control samples of known value alongside patient samples to check that each run is accurate [3][4].
  • External quality schemes compare a lab's results with hundreds of other labs. In Spain, the SEQCML schemes involve about 700 laboratories [5].
  • A reference range describes healthy people, not you. About 5% of healthy people fall outside it [8].
  • A flagged result is a reason to talk to your doctor, not a diagnosis.

The journey of a blood sample

Laboratory medicine describes the full path of a test as the "total testing process". It has three phases.

  1. Pre-analytical. Everything before the measurement: the request, your preparation, the blood draw, labelling, transport and sample handling.
  2. Analytical. The measurement itself, on an instrument, under quality control.
  3. Post-analytical. Review, validation, reporting and interpretation.

Each phase has its own risks. The analytical phase is the most controlled. One review estimated its error rate at about 0.002%, and found that errors in the other phases occur 4 to 5 times as often [2].

Phase What happens Typical checks Share of reported errors
Pre-analytical Request, preparation, blood draw, labelling, transport Identity checks, sample quality (for example haemolysis, clots) 46–68.2% across surveys [1]
Analytical Measurement on the analyser Internal quality control, calibration, external quality assessment About 15% in one Italian lab over a decade [2]
Post-analytical Review, validation, report Rules for unusual values, comparison with earlier results, professional review 18.5–47% across surveys [1]

These figures come from different studies with different definitions, so they are not directly comparable [2]. The point is the pattern: the measurement is rarely the weak link.

Analytical validation: is the measurement reliable?

Analytical validation asks one question. Did the instrument measure correctly during this run?

Internal quality control

Labs run control materials with known concentrations on the same analyser as patient samples. If a control falls outside its expected limits, the run is investigated before results are released. Many labs use statistical rules, often called Westgard rules, to decide when a control result signals a real problem. One study describes how they are applied in practice [4]. Internal quality control is a core requirement of the international standard for medical laboratories, ISO 15189 [2][3].

External quality assessment

Internal controls show that a lab is consistent with itself. External quality assessment shows how it compares with others. An outside organiser sends the same samples to many labs, and each lab's results are compared with its peers [5]. ISO 15189 also expects labs to take part in these comparisons [2][3].

In Spain, the Spanish Society of Laboratory Medicine (SEQCML) has run such schemes since 1981. It now runs 29 programmes covering 189 measurands, with about 700 participating laboratories [5]. Over 30 years, participating labs improved their analytical performance markedly [5].

A different meaning of "validation"

You may also see "validation" used for a test method. That is the work a lab does before offering a test at all, to show the method performs as intended. It happens once per method, not once per sample [3].

Clinical validation: does the result make sense?

Clinical validation, called "validación facultativa" in Spain, is the review step after the measurement. A qualified professional looks at the result in context. Typical questions include:

  • Is the sample suitable? Haemolysis and clotting are among the most common reasons a sample is unsuitable [2].
  • Do the results fit together? For example, values that would be unusual in combination.
  • Is there a large change from a previous result? Labs call this a delta check, and it is one of the rules used in automated review [6].
  • Is any value critical and in need of a prompt call to the requesting doctor?

Many labs use software rules for this first screen. Results that pass all the rules can be released automatically. Results that fail are held for a person to review. In one project across three Canadian labs, this approach went from releasing about 40–60% of tests automatically to more than 90% [6]. The rest still went to manual review.

Why a change between two results may not mean much

Every result carries some analytical variation. Your body also varies from day to day. The "reference change value" combines both to estimate whether the difference between two results is likely real [7]. It is usually calculated at 95% confidence [7]. Small changes can be within normal noise. Ask your doctor to help you read a trend, not a single number.

Reference ranges are not universal

Most reference ranges cover the middle 95% of a healthy reference group. Their limits are the 2.5th and 97.5th percentiles. That means about 5% of healthy people fall outside the range [8]. Ranges also vary with the method, the lab, age and sex [8]. Always read your result against the range printed on your own report, and discuss it with your doctor.

What happens to your sample at Santé Labs

At Santé Labs, in Barcelona, we measure blood markers and explain what each one means. Read every result against the reference range printed on your report.

Santé Labs measures and explains. We do not diagnose or treat. If any value is outside its range, take the report to your doctor.

You can book several profiles now, for example the Complete Thyroid Profile and the Basic Kidney Profile. Others, such as the Standard Lipid Profile, are coming soon.

FAQ

Does "validated" mean my result is normal? No. It means the result was measured and reviewed as reliable. A validated result can still be outside the reference range. Discuss it with your doctor.

If my result is outside the range, was there an error? Not necessarily. About 5% of healthy people fall outside a reference range by definition [8]. Your doctor can decide whether a repeat test is useful.

Why might a lab ask me to repeat a test? Usually because of a sample problem, such as haemolysis or a clot, which can make the result unreliable [2].

Can I compare results from two different labs? With care. Methods and reference ranges differ between labs [8]. Comparing results from the same lab is usually more meaningful. Talk it through with your doctor.

How can I help my sample be reliable? Follow the preparation instructions you are given, such as fasting when asked. Tell the team about medicines and supplements. Most errors happen before the measurement [1][2].

References

  1. Plebani M. Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med. 2006 – https://doi.org/10.1515/CCLM.2006.123
  2. Hawkins R. Managing the pre- and post-analytical phases of the total testing process. Ann Lab Med. 2012 – https://pmc.ncbi.nlm.nih.gov/articles/PMC3255486/
  3. Schneider F, Maurer C, Friedberg RC. International Organization for Standardization (ISO) 15189. Ann Lab Med. 2017 – https://pmc.ncbi.nlm.nih.gov/articles/PMC5500734/
  4. Peng S, et al. Practical application of Westgard Sigma rules with run size in analytical biochemistry processes in clinical settings. J Clin Lab Anal. 2021 – https://pmc.ncbi.nlm.nih.gov/articles/PMC7957980/
  5. Perich Alsina C, et al. Spanish Society of Laboratory Medicine external quality assurance programmes: evolution of the analytical performance of clinical laboratories over 30 years. Adv Lab Med. 2020 – https://pmc.ncbi.nlm.nih.gov/articles/PMC10159287/
  6. Randell EW, et al. Strategy for 90% autoverification of clinical chemistry and immunoassay test results using six sigma process improvement. Data Brief. 2018 – https://pmc.ncbi.nlm.nih.gov/articles/PMC5998219/
  7. Díaz-Garzón Marco J, Fernández-Calle P, Ricós C. Models to estimate biological variation components and interpretation of serial results: strengths and limitations. Adv Lab Med. 2020 – https://pmc.ncbi.nlm.nih.gov/articles/PMC10270238/
  8. Ozarda Y. Reference intervals: current status, recent developments and future considerations. Biochem Med. 2016 – https://www.biochemia-medica.com/en/journal/26/1/10.11613/BM.2016.001
Compartir

Plan Superhuman

Mide tu ApoB.Y más de 100 biomarcadores en total.

Una analítica completa al año en el laboratorio y un plan de acción claro.

495 € al año, con renovación anual. Cancela la renovación desde la app. Si tu médico no aprueba la solicitud, te devolvemos todo lo pagado. La lista exacta depende de tu sexo y tu edad.

Sigue leyendo

Artículos relacionados.Para leer junto a este.

Ver el blog
Ver el blog